- User guides - Get the most of your Suunto product
Looking for:
Suunto zoop novo manual -- Suunto zoop novo manual
View the manual for the Suunto Zoop Novo here, for free. This manual comes under the category Watches and has been rated by 3 suunto zoop novo manual with an average of a 8.
This manual is available in the following languages: English. Do mznual have a question about the Suunto Zoop Novo or do you need help?
Ask your question here. Suumto you have cd drive download for windows 10 question about the Suunto and the suunto zoop novo manual is not in the перейти Provide a clear and comprehensive description of the problem and your question.
The better your problem and question is described, the easier it is for other Nofo owners to provide you with a good answer. Can't find the answer to your question in the manual? Is your question not listed? Suunto Zoop Novo 1. Need help? Ask a question. A battery in my Watch has started to suunto zoop novo manual. Is the device still safe to use?
The product can still be used safely after proper cleaning. Remove the battery with gloves and clean the battery compartment with a toothbrush and vinegar.
After drying, new batteries can be inserted into the device. Is the manual of the Suunto Zoop Novo available in English? Yes, the manual of the Suunto Zoop Novo is available in English. No results. Suunto 5 Peak manual 70 pages. Suunto 9 Suunto zoop novo manual manual 76 pages.
Suunto 9 Peak Pro manual 67 pages. Suunto X3HR manual 52 pages. Suunto X10 manual pages. Suunto T3C manual pages. Omega Speedmaster Dark Side of the Moon manual 2 pages.
Manual Suunto Zoop Novo (page 1 of 73) (English).
Hide thumbs Also See for zoop novo : Quick manual 2 pages. Table Of Contents. Quick Links. Table of Contents. Previous Page. Next Page. Page 2: Table Of Contents 1 Safety Page 3 3. Page 4 5. Page 5: Safety Make sure that you fully understand the use, displays and limitations of your dive instruments.
If you have any questions about this manual or the dive computer, contact your Suunto dealer before diving with the dive computer. Always remember that YOU Insufficient training for any kind of diving, including freediving, may cause a diver to commit errors, such as incorrect use of gas mixtures or improper decompression, that may lead to serious injury or death. Page 7 DCS. Therefore, Suunto strongly recommends that the device not be used for any commercial or professional diving activities.
Ensure that you use Always check that your dive computer is functioning properly and has the correct settings before diving. Check that the display is working, the battery level is OK, tank pressure is correct, and so forth.
If there is any apparent malfunction, abort the dive immediately and safely return to the surface. Doing so may cause an electric shock or fire. Page Emergency Ascents Emergency ascents In the unlikely event that the dive computer malfunctions during a dive, follow the emergency procedures provided by your certified dive training agency to immediately and safely ascend.
Change modes by pressing [MODE]. Page Set Up Ascent rate 2. Make absolutely sure you have it set up as you want before getting into the water. Page Features Each time your Suunto Zoop Novo enters dive mode, a series of automatic checks are performed. All graphical display elements are turned ON, and the backlight and the beep are activated. After this, your altitude and personal settings are displayed along with the maximum operating depth MOD , gas content, and PO 2 values. Page 15 DIVE 1.
Page Battery Indicators 3. If you store your Suunto Zoop Novo for a long period or use it in cold temperatures, the low battery warning may appear even though the battery has enough capacity. Page Alarms, Warnings And Notifications 3. The two audible alarm types indicating indicating high or low Page 18 Sound pattern Interpretation beep Ascending Start ascending Descending Start descending Suunto Zoop Novo displays information during the alarm breaks in order to save battery life.
High priority alarms: Alarm Explanation High priority alarm followed by 'Start PO 2 value greater than the adjusted ascending' beep, value. Page 19 Alarm Explanation and an arrow points downwards. Slow down your ascent rate. SLOW blinks. Low priority alarms: Alarm type Alarm reason Low priority alarm No-decompression dive becomes a followed by 'Start decompression stop dive.
Page 20 Alarm type Alarm reason Low priority alarm followed by 'Start descending' beep, Mandatory safety stop violated. You repeated for three should descend to complete the safety minutes.
An arrow points downwards. Low priority alarm Deepstop depth reached. Make the followed by two short mandatory deepstop for the duration beeps. Page 21 Alarm type Alarm reason Low priority alarm, Defined dive time exceeded.
Low priority alarm. Defined depth reached Free dive Maximum depth value mode only. Acknowledge the alarm blinks. Page Apnea Timer 3. You can adjust the following settings: Vent. The time is increased by the increment time for each interval. Page Ascent Rate 5. To use the apnea timer: 1. The timer counts down the ventilation time.
The countdown continues up to seconds beyond the defined ventilation time. Page 24 You can view bookmarks when scrolling the dive profile in the logbook. Each bookmark records present depth, time, and water temperature. Page Time 3. To set time: 1. While in time mode, keep [DOWN] pressed. Page Dual Time 4. Repeat for minutes.
Press [MODE] to exit. When the daily alarm activates, the screen blinks and the alarm sounds for 60 seconds. Page Depth Alarm 5. You can adjust the depth according to your personal preference or switch it off. To adjust the depth alarm: 1. Page Dive History 3. The logbook contains a sophisticated dive profile for each recorded dive. The time between each data point saved in the log is based on 3. Page Dive Modes NOTE: Several repetitive dives are considered to belong to the same repetitive dive series if the no-fly time has not ended.
Page Air Mode 4. Each dive mode has its own settings which you need to adjust while in the given mode. To modify dive mode settings: 1. While in a given dive mode, keep [DOWN] pressed. This ensures correct nitrogen and oxygen calculations and the correct maximum operating depth MOD , which is based on your entered values. The timer in the center of the display shows dive time in minutes and seconds and activates at the start of the dive.
Page Free Mode Gauge mode is a bottom timer only and thus includes no decompression information or calculations. The dive time is indicated in minutes and seconds in the center of the display. Page 37 3. Suunto Zoop Novo starts the countdown as soon as you reach 1. To set the surface countdown timer: 1. Page Dive Numbering 5. Within each series, the dives are given numbers. Page Dive Time Alarm ft. The no-decompression time limit for the selected depth is shown in the center of the display.
You can adjust the surface time with [UP]. Page Error State Algorithm Lock 5. If you do not respond to these warnings, Suunto Zoop Novo enters an error state and shows Er on the display. Page Personal And Altitude Adjustments In such a condition, you should descend back below the ceiling level to continue the decompression. If you fail to do so within three 3 minutes, Suunto Zoop Novo locks the algorithm calculation and displays ER instead, as shown below.
Note that the ceiling value is no longer present. Page 42 Conservative. Some risk factors or conditions exist. More conservative. Several risk factors or conditions exist. In addition to the personal setting, Suunto Zoop Novo can be adjusted for diving at different altitudes.
This adjusts the decompression calculation according to the selected altitude adjustment. Page Power Save Mode With every dive over 10 meters 30 feet , there is a three-minute countdown for the recommended safety stop.